A

AC:

Alternating current, 50 Hz or 60 Hz

Actuation current:

The actuation current I ANZ is the current necessary to move the armature into the stroke position (see also VDE 0580)

Actuation time:

The actuation time t1 is the sum of the response delay and the stroke time t2 (see diagrams in VDE 0580)

Actuation voltage:

The actuation voltage uANZ is the voltage necessary to move the armature into the stroke position (see also VDE 0580)

Adapter:

Device for diverting the valve air connections in order to increase compatibility

Ambient temperature:

Describes the temperature of the surroundings at which valve operation is permitted under maximum allowable self-heating

Area of application:

Describes the area in which, and the way in which the valve may be deployed

Armature:

Metal part moved by magnetization in the armature system

Armature guide:

Passive component in which the medium is transported

Armature system:

Active component for controlling the medium; consists of the armature guide, magnet core and armature

B

Bi-stable:

Unit remains activated until the reset switch is operated (e.g. manual switching 1 = On – 0 = Off)

C

Casing material:

Material for encasing (shaping) the solenoid coil

Connection type, electrical:

 

  • CECC/EN 175 301-803 Type A ISO 4400
  • CECC/EN 175 301-803 Type B ISO 6952
  • Design Type B-industrial
  • CECC/EN 175 301-803 Type C ISO 15217
  • stranded wire
  • bayonet connector DIN 72585

 

Connection type, pneumatic:

 

  • KR — concentric O-rings
  • GKR — concentric O-rings with trapped exhaust air
  • SF — flange-mounted on the side
  • GSF — flange-mounted on the side, trapped exhaust air
  • ST — hose nozzle connection
  • FL — flange connection with O-rings on the underside

D

DC:

Direct current (i.e. voltage) (Half-wave or full-wave rectification, or battery voltage source)

Decay time:

The decay time is the sum of the decay delay t21 and return time t22 (see diagrams in VDE 0580)

Design Type B-industrial

Type of electronic connection

Design width:

Dimensions of the units for determining the space requirement and the block design

Direct current/voltage:

Current/voltage rectification with a ripple of < 45%

Duroplast:

Casing material for solenoid coils with high temperature stability

Duty ratio:

Is the ratio of the power-on time to the total running time

E

EMV:

Electromagnetic compatibility, interference immunity against rapid transient disturbances (connection to power lines)

Exhaust throttle:

By means of the exhaust throttle the flow rate may be adjusted by turning the adjustment screw (on the exhaust side)

F

Fastening plate:

Single assembly component for locking and attaching the armature system (flange) in the valve housing

Flow rate:

Volume per time unit; quantity of the gaseous medium that escapes through a defined opening within a specified time interval

Frequency:

Number of switching operations / oscillations / time unit

H

High voltage test:

Test according to VDE 0110-1 to check for compliance with permissible air gaps and creepage distances (arcing, electrical breakdown)

I

Insulation Class:

Gives the limit temperature of insulation materials according to VDE 0301-1 (DIN IEC 60 085) e.g. Insulation Class "F" = limit temperature of 155°C

IP:

See protection class

L

LED:

"Light Emitting Diode": active indicator showing that the device is switched on

M

M12:

Threaded connection with a 12 mm screw thread for the electrical connection of the solenoid coil

Manual operation:

Manual switching of an otherwise electrically operated solenoid valve

Medium:

The gas or liquid to be transported

Monostable:

Switching state during manual operation (e.g. pressed hand operation)

N

NC:

Normally closed solenoid valve / solenoid operator is closed in the currentless state

NO:

Normally open solenoid valve / solenoid operator is open in the currentless state

Nominal flow rate:

See flow rate

Nominal opening size:

Describes the size of flow opening for the medium at the valve inlet

O

Operating mode:

vertical, horizontal

Operating pressure:

Sum of all forces exerted by a gaseous medium on the container wall (armature system / valve system)

Operating voltage:

Voltage at which the solenoid valve may be brought into operation according to specifications

P

Power Class:

Gives the power in Watts for DC and in Volt-Amperes for AC necessary to operate a valve according to the nominal opening size / pressure.

Pressure regulator:

Valve for setting the required pressure (e.g. Inlet 10bar – Outlet adjustable from 3-10bar)

Protection Class:

See Ex-information sheet

PTB:

German Federal Institute of Physics and Metrology; Certification Institute

Pulling force:

(Lifting force according to VDE 0580) Magnetic force that acts outwardly under consideration of the associated mass components of the armature

S

Seal insert:

Elastomer made of different materials used as the sealing material

Shut-off valve, pilot-operated:

Shuts off the flow of the medium

Solenoid coil:

Component that consists of the excitation winding and bundles and directs the magnetic flux.

Solenoid valve:

A unit which, on account of its construction and the governing technical data, is suitable for actuating valves for liquids and gases

Steady-state excess temperature:

Difference between the temperature of the solenoid coil and the ambient temperature once temperature equilibrium has been attained in the switched-on state. After 60 minutes as a rule, see VDE 0580

T

Temperature Class:

Gives the maximum permissible surface temperature in classes above Class II according to EN 50014

  • T3 = 200°C
  • T4 = 135°C
  • T5 = 100°C
  • T6 = 85°C

 

Temperature:

Given in degrees Centigrade (for ambient temperature, upper and lower limit temperature, self-heating)

Thermoplast:

Plastic used for moulding plastic parts (recyclable)

Throttle check valve:

A throttle check valve combines two different functions:
throttling and prevention of return flow

Tightness:

Leakage / time unit; non-desired quanitity of the gaseous medium that escapes in the switched-on or switched-off state of a valve during a time interval

V

Valve housing:

The valve housing has a defined pneumatic interface

Valve seating:

(see nominal opening size) Nozzle in the valve system / valve solenoid that affects the discharge and flow characteristics

Valve solenoid:

Consists of an armature system, a solenoid coil and possibly fixing material

Valve system:

Consists of an armature system and valve housing with corresponding pneumatic interfaces

  • KR — Concentric O-Rings
  • GKR — concentric O-rings with trapped exhaust air
  • CNOMO — CNOMO hole pattern
  • SF — side-mounted flange
  • FL — flange mounting on the underside

 

VDE:

German Association for Electrical, Electronic and Information Technologies

Vent protection unit:

Serves to direct the flow of escaping air after the valve has been switched off

Voltage:

Gives the value for a device to which the operational and power characteristics are related

Voltage tolerance:

Gives the permissible voltage deviation value

W

Winding:

Describes the number of windings with laquered copper wire on the solenoid coil